Selecting the right bottletop filter depends on your specific membrane requirements, volume needs, and workflow preferences. These eight sterile units offer various configurations, from funnel-only setups to complete single-piece systems.
Consider the membrane material, pore size, and capacity when making your choice. Some units feature ergonomic designs for easier handling, while others focus on quick-connect mechanisms for hands-free operation. This comparison helps you match the filter to your lab's specific filtration tasks.
Our 3 picks for different needs
Argos BNY4550 500 mL Nylon Unit
Choose this Argos unit if your protocol specifically requires a nylon membrane with a 0.45 µm pore size.
Read the details
Celltreat 229723 500 mL PES System
This Celltreat system is ideal for labs using different hose diameters due to its angled three-size adapter.
Read the details
Nalgene 569-0020 500 mL Filter System
Select this Nalgene system if you prioritize tapered sides with grips and a wide stable base for bench work.
Read the detailsAll products, in detail
Foxx Life Sciences Autofil 500 mL Funnel Only
This funnel-only unit features a 0.2 µm PES membrane and forward-facing graduation marks for easy reading. The listing notes that the Autofil is available as a complete system or funnel only, and this specific variant is sold as the funnel only. This configuration is suitable for labs that prefer to manage their own bottle inventory while using the Autofil filtration mechanism.
- Includes 0.2 µm PES asymmetric membrane
- Sold as funnel only with Quick-Connect base
Foxx Life Sciences EZLabpure 1000 mL Unit
The EZLabpure series offers a ready-to-use single-piece design with a 0.1 µm PES membrane. It features a secure vacuum connection for easy setup and hands-free operation. The high-quality PES membrane is designed for clear results. This 1000 mL capacity unit is ideal for users who need a larger volume filtration setup without complex assembly.
The single-piece construction simplifies the workflow for high-throughput applications.
- Single-piece design with 0.1 µm PES membrane
- 1000 mL capacity for larger volume filtration
Argos BNY4550 500 mL Nylon Unit
This unit uses a nylon membrane with a 0.45 µm pore size, distinguishing it from PES options. It features an optically clear polystyrene funnel and a 100% virgin polypropylene bottle. The unit is non-pyrogenic and gamma irradiated for sterility. Engraved graduations provide accuracy, while the wide bottle opening allows for easy access and pouring.
It is individually wrapped with peel-open packaging for convenience. This option is suitable for applications requiring nylon membrane compatibility.
- Nylon membrane with 0.45 µm pore size
- Optically clear polystyrene funnel with wide opening
Celltreat 229723 500 mL PES System
The Celltreat system features an angled hose barb adapter that fits three size hose diameters and prevents tipping. It includes an improved filter support designed for faster flow rates. Molded graduation marks on the bottle top are easy to read. The unit uses a 0.10 µm PES membrane and is constructed from polystyrene.
This design is beneficial for labs using various hose sizes, as the angled adapter provides flexibility in connection. The pack of 12 offers a consistent supply for routine filtration tasks.
- Angled hose barb adapter fits three hose diameters
- 0.10 µm PES membrane with improved filter support
Foxx Life Sciences Autofil 1000 mL Unit
This complete Autofil unit includes a 0.2 µm PES membrane and a 1000 mL capacity. It features forward-facing, large, raised graduation marks for easy reading. The Quick-Connect pedestal base or cradle ring allows for hands-free filtration. Secure grasp bottle cap technology ensures a stable seal.
The unit is available in various membrane sizes, but this specific listing is for the 0.2 µm variant. It is a good choice for users needing a larger volume capacity with the Autofil's secure connection features.
- 1000 mL capacity with 0.2 µm PES membrane
- Quick-Connect base for hands-free operation
Foxx Life Sciences Autofil 500 mL Unit
This 500 mL Autofil unit features a 0.2 µm PES membrane and is conveniently sold presterilized. It includes forward-facing, large, raised graduation marks for easy reading. The Quick-Connect pedestal base or cradle ring allows for hands-free filtration. Secure grasp bottle cap technology provides a reliable seal.
The unit is part of a case of 12, offering a consistent supply for labs. This configuration is suitable for standard volume filtration where the Autofil's secure grasp and quick-connect features are desired.
- 500 mL capacity with 0.2 µm PES membrane
- Presterilized and sold in a case of 12
Nalgene 567-0020 1000 mL Rapid-Flow Unit
The Nalgene Rapid-Flow unit features a 90 mm diameter and 1000 mL capacity. It uses a PES membrane with a 0.2 µm pore size. The design is intended for rapid filtration workflows. The large diameter may facilitate faster flow rates compared to smaller diameter units.
This unit is sold in a case of 12. It is a suitable option for labs requiring high-volume filtration with a standard PES membrane. The 90 mm diameter is a specific design feature that distinguishes it from other Nalgene models.
- 90 mm diameter with 1000 mL capacity
- PES membrane with 0.2 µm pore size
Nalgene 569-0020 500 mL Filter System
This Nalgene filter system is made in the United States and features a 500 mL capacity. It uses a PS (polystyrene) construction with a 0.2 µm pore size. The filter units have tapered sides and grips to make them easier to handle. A wide base provides stability on the bench top.
The package weight is 5.0 lbs. This design focuses on ergonomic handling and stability, which is beneficial for users who frequently move units or work in crowded bench spaces. The US manufacturing is a specific attribute for those with procurement preferences.
- Tapered sides with grips for easier handling
- Wide base for bench top stability
Head-to-Head Comparisons
Foxx Autofil Funnel Only vs Complete 500 mL Unit
The Foxx Autofil funnel only variant is sold as the funnel only, allowing you to use your existing bottles, while the complete 500 mL unit is a full system. Both feature the 0.2 µm PES membrane. The funnel only option is suitable for labs that already have a standardized bottle inventory.
The complete unit is better for those who want a ready-to-use package. The choice depends on whether you prefer to manage your own bottle supply or use the integrated system.
Argos Nylon Membrane vs Foxx PES Membrane
The Argos BNY4550 uses a nylon membrane with a 0.45 µm pore size, while the Foxx Autofil uses a PES membrane with a 0.2 µm pore size. Nylon membranes are often chosen for specific protein filtration applications, whereas PES is common for general sterilization. The Argos unit features an optically clear polystyrene funnel and wide bottle opening.
The Foxx unit offers a Quick-Connect base for hands-free operation. Your choice should be driven by the chemical compatibility and pore size required by your specific protocol.
Celltreat Angled Adapter vs Nalgene Ergonomic Base
The Celltreat 229723 features an angled hose barb adapter that fits three hose diameters, preventing tipping. The Nalgene 569-0020 focuses on ergonomic handling with tapered sides and grips, plus a wide base for stability. The Celltreat design is beneficial for labs with variable hose sizes.
The Nalgene design is better for users who prioritize easy manual handling and bench stability. The decision rests on whether you need hose flexibility or ergonomic grip features.
Buying Guide
Membrane Material and Pore Size
The membrane material determines chemical compatibility and filtration efficiency. PES membranes are common for general sterilization, while nylon membranes are often used for protein applications. Pore size, such as 0.1 µm, 0.2 µm, or 0.45 µm, dictates the level of filtration. Check your protocol requirements to ensure the membrane material and pore size match your needs.
This is the most critical factor in selecting a bottletop filter.
Capacity and Volume Needs
Bottletop filters come in 500 mL and 1000 mL capacities. Choose 500 mL units for standard sample sizes and 1000 mL units for larger volume filtration. The capacity should match the typical volume of your samples to avoid unnecessary waste or insufficient capacity. Consider your workflow volume when selecting the size.
Larger units may require more space on the bench but reduce the number of filters needed for high-volume tasks.
Design and Ergonomics
Design features like tapered sides, grips, and wide bases affect handling and stability. Some units feature quick-connect bases for hands-free operation, which can improve workflow safety. Others focus on ergonomic grips for easier manual handling. Consider your bench space and how you typically handle filters.
A stable base is important for preventing spills, while quick-connect features can streamline the setup process for high-throughput labs.
Compatibility with Vacuum Systems
Ensure the filter unit is compatible with your existing vacuum filtration systems. Some units feature specific hose barb adapters that fit multiple hose diameters, while others have standard connections. Check the connection type to ensure it matches your vacuum pump or manifold. Compatibility is essential for a secure and leak-free connection.
If you use a specific brand of vacuum system, verify that the filter unit is designed to work with it.
Frequently Asked Questions
What is the difference between PES and nylon membranes?
PES membranes are commonly used for general sterilization and have good chemical resistance. Nylon membranes are often chosen for protein filtration due to their lower protein binding. The choice depends on your specific application and the chemicals involved in your protocol.
Are these filters sterile?
Yes, the listed bottletop filters are sterile. The Nalgene 567-0020 is described as a sterile filter unit in its title, though specific sterilization methods are not detailed in the provided features.
Can I use these filters with any vacuum pump?
Most bottletop filters are designed to work with standard vacuum pumps, but you should check the connection type. Some units have specific hose barb adapters that fit multiple hose diameters. Ensure the connection is compatible with your vacuum system to prevent leaks.
How do I choose the right pore size?
The pore size determines the level of filtration. 0.2 µm is common for sterilization, while 0.45 µm is often used for clarification. Choose the pore size that matches your protocol requirements. Smaller pore sizes provide finer filtration but may have slower flow rates.
This article is part of our complete guide Toys & Games — browse all our comparisons and buying guides.
Last update on 2026-11-21 / Affiliate links / Images from Amazon Product Advertising API