Selecting the right voltage monitoring relay depends on your system's voltage type, phase configuration, and installation space. Whether you are protecting a single-phase motor or a complex three-phase industrial line, the relay must match your specific electrical requirements.
This guide compares eight relays based on their documented voltage ranges, contact capacities, and mounting styles. We focus on how each unit handles over and under-voltage conditions to help you choose the appropriate protection for your equipment.
Our pick: Voltage Monitor Module DC 0-99.9V. This module offers a wide 0-99.9V adjustable range with a digital display, ideal for custom battery protection setups.
Our 3 picks for different needs
JVR800-2 3 Phase Voltage Monitoring Relay
The JVR800-2 monitors phase loss, sequence, and unbalanced voltage, making it suitable for complex three-phase systems.
Read the details
Voltage Monitor Module DC 0-99.9V
This module offers a wide 0-99.9V adjustable range with a digital display, ideal for custom battery protection setups.
Read the details
GEYA GRV8-01 Single Phase Voltage Relay
The GEYA GRV8-01 features a 18mm width and True RMS measurement, fitting tight panels for 110-240V applications.
Read the detailsAll products, in detail
Voltage Monitor Module DC 0-99.9V
This module features a digital display for DC voltage detection and includes a relay output for control. It supports an adjustable detection range from 0 to 99.9V, making it suitable for battery protection or discharge metering. The unit includes two buttons for operation and a clear LED display for checking values.
It comes with a protective cover. This compact board is ideal for hobbyists or technicians needing a simple, adjustable voltage threshold controller for low-voltage DC circuits.
- Adjustable voltage detection range of DC 0 to 99.9V
- Includes digital display and two operation buttons
GEYA GRV8-01 Single Phase Voltage Relay
The GEYA GRV8-01 is a single-phase voltage relay designed for AC/DC 110V-240V applications. It uses True RMS measurement to control its own supply voltage. Users can select the operation mode via a knob, and the relay status is indicated by an LED. With an ultra-small 18mm width and 35mm rail mounting, it fits into tight panel spaces.
This model is suitable for protecting single-phase equipment in industrial or commercial settings where compact DIN rail installation is required.
- True RMS voltage measurement with <1% accuracy
- Ultra-small 18mm width for 35mm DIN rail mounting
LiebeWH DC 48V Voltage Monitoring Relay
This LiebeWH relay monitors DC circuits for over and under-voltage faults without requiring an additional auxiliary power supply. It features two indicator lights to show working conditions and includes two sets of normally open and normally closed contacts. The action time for the over-voltage relay is adjustable.
Designed for standard modular rail installation, it is suitable for protecting DC motors, batteries, UPS power supplies, and industrial control systems from voltage fluctuations.
- No additional auxiliary power supply required
- Two sets of normally open and normally closed contacts
JVR800-2 3 Phase Voltage Monitoring Relay
The JVR800-2 is a three-phase voltage relay that monitors overvoltage, undervoltage, phase loss, phase sequence, and unbalanced voltage. It integrates a three-phase voltage protector, chronograph, and counter into a single unit. Two reset modules are optional, allowing for manual or automatic resetting. An LCD display shows data for easy reading.
This relay is designed for complex three-phase industrial systems where comprehensive phase monitoring and sequence protection are necessary.
- Monitors phase loss, sequence, and unbalanced voltage
- Integrated chronograph and counter with LCD display
YWBL-WH SVR1000 Single Phase Relay
The YWBL-WH SVR1000 features a modular design for quick installation on 35mm DIN rails. It supports universal voltage detection for AC/DC inputs, covering 12-600V AC and 12-400V DC ranges. The built-in LCD displays real-time voltage values and fault alerts in simplified Chinese characters. This relay is suitable for technicians working in mixed-power systems, such as HVAC or solar installations, where auto-detection prevents misconfiguration errors during maintenance.
- Supports 12-600V AC and 12-400V DC input ranges
- LCD display shows data in simplified Chinese characters
GUETNEU 4 Channel Relay Board 24V
This GUETNEU relay board is a 4-channel module designed to amplify current for output loads in PLC and microprocessor systems. It operates on 24V AC/DC and has a rated load current of 10A. The board features LED indicators for signal status and includes overvoltage and surge suppression protection.
It mounts on a DIN rail but can be removed from the bracket to fit in narrow spaces. This module is useful for protecting key control systems by isolating high-current loads from sensitive electronics.
- 4-channel SPDT relay with 10A rated load current
- Includes overvoltage and surge suppression protection
YWBL-WH DC 48V 6A Voltage Relay
This YWBL-WH relay continuously monitors DC circuits for over and under-voltage faults. It features adjustable thresholds for overvoltage (13-17V) and undervoltage (10-14V) with an action delay of 0.1 to 15 seconds. The unit has two sets of contacts with a 6A 250VAC capacity and two LED indicator lights.
It is designed for DC 48V applications and mounts on standard 35mm DIN rails. This model is ideal for protecting DC motors, batteries, and UPS systems in industrial control panels.
- Adjustable action delay time from 0.1 to 15 seconds
- 6A 250VAC contact capacity for DC 48V systems
DC Voltage Monitoring Relay 35mm Rail
This voltage monitoring relay safeguards connected equipment by tripping on both over and under-voltage conditions. It is designed for simple installation on standard 35mm DIN rails found in electrical panels. Users can set custom trip points and delay times to match specific DC system requirements.
The relay provides real-time monitoring to protect motors or batteries from faults. It is suitable for UPS systems, battery banks, industrial controls, and DC switchgear applications.
- Adjustable custom trip points and delay times
- Designed for standard 35mm DIN rail installation
Head-to-Head Comparisons
LiebeWH vs YWBL-WH: DC 48V Protection
Both the LiebeWH and YWBL-WH relays are designed for DC 48V applications with DIN rail mounting. The LiebeWH model highlights that it does not require an additional auxiliary power supply and features two sets of contacts. The YWBL-WH model specifies a 6A 250VAC contact capacity and detailed adjustable thresholds for overvoltage and undervoltage.
If you need specific contact ratings documented in the listing, the YWBL-WH provides those details. If you prioritize a design that explicitly states no auxiliary power is needed, the LiebeWH is a clear choice. Both offer real-time monitoring for DC systems.
JVR800-2 vs SVR1000: Phase and Range
The JVR800-2 is a three-phase relay that monitors phase loss, sequence, and unbalanced voltage, integrating a chronograph and counter. The YWBL-WH SVR1000 is a single-phase relay with universal AC/DC detection supporting up to 600V AC. The JVR800-2 is suitable for three-phase industrial systems where sequence protection is critical.
The SVR1000 is better for single-phase or mixed-power systems where a wide voltage range and auto-detection are needed. The choice depends on whether your system is single or three-phase.
Voltage Monitor Module vs Relay Board
The Voltage Monitor Module is a controller board with a digital display and adjustable 0-99.9V range, designed to control a relay output. The GUETNEU Relay Board is a 4-channel module that amplifies current for loads, featuring surge suppression. The monitor module is for detecting voltage thresholds and triggering actions.
The relay board is for switching multiple loads with high current capacity. If you need to monitor a specific voltage level, choose the monitor module. If you need to switch multiple 24V loads, choose the relay board.
Buying Guide
Voltage Type and Range
Determine if your system operates on AC or DC and the specific voltage range. Some relays, like the GEYA GRV8-01, are rated for 110-240V AC/DC. Others, like the YWBL-WH SVR1000, support 12-600V AC. Ensure the relay's input range covers your system's nominal voltage and potential fluctuations.
Check the product specifications to confirm the voltage type matches your application.
Phase Configuration
Identify if your equipment is single-phase or three-phase. Single-phase relays monitor over and under-voltage for one phase. Three-phase relays, such as the JVR800-2, also monitor phase loss, sequence, and unbalance. Using a single-phase relay on a three-phase system will not provide full protection against phase-related faults.
Match the relay's phase capability to your motor or power supply configuration.
Contact Capacity and Type
Review the relay's contact ratings to ensure they can handle the load current. Some relays specify 10A or 6A capacities. The type of contact, such as SPDT or multiple sets of normally open/closed contacts, determines how you can wire the protection circuit. Ensure the contact capacity exceeds the current of the device you are protecting.
Consider the number of channels if you need to control multiple outputs simultaneously.
Installation and Mounting
Most relays in this category use 35mm DIN rail mounting, which is standard for industrial panels. Check the physical dimensions if space is limited, as some models are ultra-small. Consider if the relay requires an auxiliary power supply or operates from the line voltage. Ensure the mounting style fits your existing panel layout and that the relay can be securely installed for long-term reliability.
Frequently Asked Questions
What is the difference between over and under-voltage protection?
Over-voltage protection trips the relay when voltage exceeds a set upper limit, while under-voltage protection trips when it falls below a lower limit. Many relays offer both, allowing you to set a safe operating window. This protects equipment from damage due to high or low voltage conditions.
Can I use a single-phase relay for a three-phase system?
A single-phase relay only monitors one phase and cannot detect phase loss or sequence errors in a three-phase system. For full protection of three-phase motors, you need a three-phase voltage monitoring relay that checks all phases and their relationship.
Do these relays require an external power supply?
Some relays, like the LiebeWH model, state that no additional auxiliary power supply is required, operating from the line voltage. Others may require a separate power source for the control circuit. Always check the specific product specifications to determine the power requirements for your installation.
How do I adjust the voltage thresholds?
Most relays in this category feature adjustable settings via knobs or buttons. You can set the upper and lower voltage limits to match your equipment's requirements. Some models also allow you to adjust the delay time before the relay trips, providing flexibility in response to transient faults.
This article is part of our complete guide Electronics — browse all our comparisons and buying guides.
Last update on 2026-11-27 / Affiliate links / Images from Amazon Product Advertising API