Selecting the right lab ultrafiltration membrane filter depends on your sample volume, the molecular weight of your target analyte, and your specific workflow requirements. Whether you are concentrating small peptides or retaining large antibodies, the molecular weight cut-off (MWCO) and membrane area are critical factors.

This guide compares seven options, including centrifugal tubes in 4 mL and 15 mL sizes and a hollow fiber module. We examine the documented features of each, such as membrane material, maximum centrifugal force, and specific applications, to help you identify the best fit for your laboratory needs.

Our pick: Membrane Solutions 4 mL 10 kDa Ultrafiltration Filter. The 4 mL capacity and 10 kDa MWCO make this suitable for concentrating small peptide or oligonucleotide samples in a compact footprint.

AT A GLANCE

Our 3 picks for different needs

Membrane Solutions Ultra Centrifugal Filter 4ml, 8 Pack 10kDa Ultrafiltration Centrifuge Tube with...
01Small Volume 10 kDa Filtration

Membrane Solutions 4 mL 10 kDa Ultrafiltration Filter

The 4 mL capacity and 10 kDa MWCO make this suitable for concentrating small peptide or oligonucleotide samples in a compact footprint.

Read the details
Membrane Solutions Ultra Centrifugal Filter 15ml, 4 Pack 100kDa Ultrafiltration Centrifuge Tube with...
02Large Volume 100 kDa Filtration

Membrane Solutions 15 mL 100 kDa Ultrafiltration Filter

The 15 mL capacity and 100 kDa MWCO allow for the retention of larger macro molecules like antibodies during buffer exchange.

Read the details
Lab+ 30kDa 1.0mm Ultrafiltration Hollow Fiber Filter mPES Membrane 30cm
07High Viscosity Hollow Fiber

Lab+ 30 kDa 1.0 mm Hollow Fiber Filter

The 1.0 mm fiber ID and autoclavable design are documented as suitable for high viscosity or high cell density applications.

Read the details

All products, in detail

Membrane Solutions Ultra Centrifugal Filter 4ml, 8 Pack 10kDa Ultrafiltration Centrifuge Tube with...
01Small Volume 10 kDa Filtration

Membrane Solutions 4 mL 10 kDa Ultrafiltration Filter

This 4 mL centrifugal filter uses a PES membrane with a 10 kDa molecular weight cut-off. It features a vertical design with a 3.5 cm² effective membrane area, which the seller states provides high sample recovery. The high-purity polypropylene container is graduated and non-sterile. It is suitable for concentrating small peptides, oligonucleotides, and enzymes.

The maximum centrifugal force is 4000x g in a swing bucket rotor and 6000x g in a fixed angle rotor for ultrafiltration, with a microfiltration limit of 10000x g in a fixed angle rotor. This compact size is ideal for small-volume sample processing.

  • 4 mL capacity with 3.5 cm² effective membrane area
  • 10 kDa PES membrane with low protein and nucleic acid binding
Membrane Solutions Ultra Centrifugal Filter 15ml, 4 Pack 100kDa Ultrafiltration Centrifuge Tube with...
02Large Volume 100 kDa Filtration

Membrane Solutions 15 mL 100 kDa Ultrafiltration Filter

This 15 mL centrifugal filter utilizes a PES membrane with a 100 kDa molecular weight cut-off. It offers a larger effective membrane area of up to 7.2 cm² compared to smaller tubes. The high-purity polypropylene container is graduated and non-sterile. It is designed for concentrating macro molecules like antibodies and enzymes.

The maximum centrifugal force is 4000x g in a swing bucket rotor and 5000x g in a fixed angle rotor for ultrafiltration, with a microfiltration limit of 6000x g in a fixed angle rotor. This higher MWCO allows for the retention of larger proteins during buffer exchange or concentration.

  • 15 mL capacity with up to 7.2 cm² effective membrane area
  • 100 kDa PES membrane for retaining larger macro molecules
10 kDa Ultrafiltration Centrifuge Tubes, 15 mL PES Membrane Centrifugal Filter Units, Protein...
03

15 mL 10 kDa PES Ultrafiltration Centrifuge Tubes

These 15 mL centrifugal filters feature a premium PES membrane with a 10 kDa molecular weight cut-off. The design is intended for efficient molecular separation with low protein binding. The seller highlights the ability to perform complete buffer replacement or desalting within minutes, which reduces preparation time compared to traditional dialysis methods.

These tubes are suitable for protein concentration, DNA purification, and buffer exchange. They are sold as a pack of 8 laboratory consumables. The specific maximum centrifugal force limits are not detailed in the provided source data for this specific listing.

  • 15 mL capacity with 10 kDa PES membrane
  • Designed for rapid buffer exchange and desalting
Membrane Solutions Ultra Centrifugal Filter 15ml, 4 Pack 5kDa Ultrafiltration Centrifuge Tube with...
04

Membrane Solutions 15 mL 5 kDa Ultrafiltration Filter

This 15 mL centrifugal filter uses a PES membrane with a 5 kDa molecular weight cut-off. It features a vertical design with an effective membrane area of up to 7.2 cm². The high-purity polypropylene container is graduated and non-sterile. It is ideal for concentrating small peptides, oligonucleotides, and nucleic acids.

The maximum centrifugal force is 4000x g in a swing bucket rotor and 5000x g in a fixed angle rotor for ultrafiltration, with a microfiltration limit of 6000x g in a fixed angle rotor. The lower MWCO is suitable for applications requiring the retention of smaller molecules while allowing salts and small impurities to pass.

  • 15 mL capacity with up to 7.2 cm² effective membrane area
  • 5 kDa PES membrane for retaining smaller molecules
Membrane Solutions Ultra Centrifugal Filter 15ml, 4 Pack 30kDa Ultrafiltration Centrifuge Tube with...
05

Membrane Solutions 15 mL 30 kDa Ultrafiltration Filter

This 15 mL centrifugal filter utilizes a PES membrane with a 30 kDa molecular weight cut-off. It offers a larger effective membrane area of up to 7.2 cm². The high-purity polypropylene container is graduated and non-sterile. It is designed for concentrating macro molecules like enzymes and antibodies.

The maximum centrifugal force is 4000x g in a swing bucket rotor and 5000x g in a fixed angle rotor for ultrafiltration, with a microfiltration limit of 6000x g in a fixed angle rotor. This MWCO is a common choice for retaining medium-sized proteins during purification workflows.

  • 15 mL capacity with up to 7.2 cm² effective membrane area
  • 30 kDa PES membrane for medium-sized protein retention
Membrane Solutions Ultra Centrifugal Filter 15ml, 4 Pack 10kDa Ultrafiltration Centrifuge Tube with...
06

Membrane Solutions 15 mL 10 kDa Ultrafiltration Filter

This 15 mL centrifugal filter uses a PES membrane with a 10 kDa molecular weight cut-off. It features a vertical design with an effective membrane area of up to 7.2 cm². The high-purity polypropylene container is graduated and non-sterile. It is ideal for concentrating small peptides, oligonucleotides, and nucleic acids.

The maximum centrifugal force is 4000x g in a swing bucket rotor and 5000x g in a fixed angle rotor for ultrafiltration, with a microfiltration limit of 6000x g in a fixed angle rotor. This size and MWCO combination is suitable for standard protein and nucleic acid concentration tasks.

  • 15 mL capacity with up to 7.2 cm² effective membrane area
  • 10 kDa PES membrane with low binding characteristics
Lab+ 30kDa 1.0mm Ultrafiltration Hollow Fiber Filter mPES Membrane 30cm
07High Viscosity Hollow Fiber

Lab+ 30 kDa 1.0 mm Hollow Fiber Filter

This hollow fiber filter uses a modified hydrophilic PES membrane with a 30 kDa molecular weight cut-off. It features a 1.0 mm fiber internal diameter and a 30 cm length. The seller states that the 1.0 mm fiber ID is suitable for products with high cell density, high solid content, or high viscosity.

This specific module is autoclavable. It is non-sterile and reusable after washing with 0.5 M NaOH solution. It is designed for purification, concentration, and diafiltration of proteins, as well as clarification of cells in fermentation broth. The materials comply with USP Class VI standards.

  • 30 kDa mPES hollow fiber with 1.0 mm ID and 30 cm length
  • Autoclavable and reusable with NaOH washing

Head-to-Head Comparisons

Membrane Solutions 4 mL vs 15 mL 10 kDa Filters

Both the Membrane Solutions 4 mL and 15 mL filters use a 10 kDa PES membrane, but they differ significantly in capacity and membrane area. The 4 mL tube has an effective membrane area of 3.5 cm², while the 15 mL tube offers up to 7.2 cm².

The 15 mL tube is suitable for larger sample volumes, whereas the 4 mL tube is better for small-scale processing. The maximum centrifugal force limits also differ; the 4 mL tube supports up to 6000x g in a fixed angle rotor for ultrafiltration, while the 15 mL tube supports up to 5000x g.

Choose the 4 mL for small volumes and the 15 mL for larger batches.

5 kDa vs 100 kDa MWCO in 15 mL Tubes

The Membrane Solutions 15 mL filters come in different MWCO options, such as 5 kDa and 100 kDa. The 5 kDa membrane retains smaller molecules, making it suitable for concentrating small peptides or oligonucleotides while allowing salts to pass. The 100 kDa membrane retains larger macro molecules like antibodies and enzymes.

Both use the same 15 mL high-purity polypropylene container with a 7.2 cm² membrane area. The choice depends entirely on the size of the molecule you wish to retain. If you are working with large proteins, the 100 kDa option is the appropriate selection.

Centrifugal Tube vs Hollow Fiber Module

The centrifugal tube is designed for batch processing in a standard centrifuge, with a maximum force of 5000x g in a fixed angle rotor for ultrafiltration. The hollow fiber module is designed for continuous or semi-continuous processing, with a 1.0 mm fiber ID suitable for high viscosity or high cell density products.

The hollow fiber is autoclavable and reusable, whereas the centrifugal tube is a consumable. The choice depends on whether you need batch concentration or continuous purification.

Buying Guide

Selecting the Correct Molecular Weight Cut-Off

The molecular weight cut-off (MWCO) determines the size of molecules retained by the membrane. For retaining small peptides or oligonucleotides, a lower MWCO like 5 kDa or 10 kDa is appropriate. For retaining larger proteins like antibodies, a higher MWCO like 30 kDa or 100 kDa is needed.

Always select an MWCO that is significantly lower than the molecular weight of your target analyte to ensure retention. If you are unsure, consider the specific application, such as buffer exchange or concentration, to guide your choice.

Understanding Membrane Area and Sample Volume

The effective membrane area affects the speed of filtration and the maximum sample volume that can be processed. A larger membrane area, such as the 7.2 cm² found in 15 mL tubes, allows for faster processing of larger volumes. Smaller tubes, like the 4 mL with 3.5 cm² area, are suitable for smaller samples.

When selecting a filter, ensure the sample volume does not exceed the recommended maximum for the specific tube size to avoid overflow or reduced efficiency. Check the product specifications for the maximum fill volume.

Centrifugal Force and Rotor Compatibility

Each filter has a maximum centrifugal force limit that must not be exceeded. The Membrane Solutions 4 mL tube supports up to 4000x g in a swing bucket rotor and 6000x g in a fixed angle rotor for ultrafiltration. The 15 mL tubes support up to 4000x g in a swing bucket rotor and 5000x g in a fixed angle rotor for ultrafiltration.

Always verify that your centrifuge rotor and speed settings are within these limits to prevent damage to the membrane or container. Exceeding the maximum force can compromise the integrity of the filter.

Choosing Between Centrifugal Tubes and Hollow Fibers

Centrifugal tubes are ideal for batch processing and are typically used in standard laboratory centrifuges. They are convenient for small to medium volume samples. The hollow fiber is reusable and autoclavable, which may be beneficial for long-term use. Consider your workflow, sample volume, and equipment availability when deciding between these two formats.

For standard lab work, centrifugal tubes are often the simpler choice.

Frequently Asked Questions

What is the difference between 10 kDa and 30 kDa membranes?

The 10 kDa membrane retains molecules smaller than 10,000 Daltons, suitable for small peptides and oligonucleotides. The 30 kDa membrane retains molecules smaller than 30,000 Daltons, suitable for medium-sized proteins. Choose the MWCO based on the size of the molecule you wish to retain.

Are these filters sterile?

The Membrane Solutions centrifugal filters are listed as non-sterile. If sterility is required for your application, you may need to look for sterile variants or perform additional sterilization steps.

Can I use these filters in a swing bucket rotor?

Yes, the Membrane Solutions centrifugal filters are compatible with swing bucket rotors. The maximum centrifugal force in a swing bucket rotor is 4000x g for both the 4 mL and 15 mL tubes. Always ensure your centrifuge settings do not exceed this limit to maintain filter integrity.

What is the effective membrane area of the 15 mL filters?

The Membrane Solutions 15 mL ultrafiltration centrifugal tubes have an effective membrane area of up to 7.2 cm². This larger area compared to the 4 mL tube allows for faster processing of larger sample volumes. The 4 mL tube has an effective area of 3.5 cm².

Last update on 2026-11-21 / Affiliate links / Images from Amazon Product Advertising API