Selecting the right nonbinding microplate depends on your specific assay requirements, including well count, bottom shape, and wall color. These six options from Greiner Bio-One and Corning offer distinct configurations to suit various laboratory needs.
Whether you need high-density 384-well plates for screening or standard 96-well plates for routine work, the surface treatment and physical design play a critical role in assay performance. This comparison helps you match the plate features to your experimental goals.
Our pick: Greiner Bio-One 651901 Clear V-Bottom 96-Well Microplate. The clear polystyrene material allows for easy visual inspection of samples in a standard 96-well format.
Our 3 picks for different needs
Corning 3574 White Flat-Bottom 384-Well Microplate
The white walls are specifically designed to reduce well-to-well crosstalk during luminescent assays.
Read the details
Corning 3575 Black Flat-Bottom 384-Well Microplate
The black walls reduce autofluorescence, offering a higher signal-to-background ratio for sensitive assays.
Read the details
Greiner Bio-One 651901 Clear V-Bottom 96-Well Microplate
The clear polystyrene material allows for easy visual inspection of samples in a standard 96-well format.
Read the detailsAll products, in detail
Greiner Bio-One 651901 Clear V-Bottom 96-Well Microplate
This clear polystyrene microplate features a conical V-bottom design in a 96-well format. It is part of a pack of 40 plates, making it suitable for high-throughput screening or routine laboratory work. The clear walls allow for visual inspection of samples, while the V-bottom shape facilitates complete liquid drainage.
This option is ideal for researchers who need a standard clear plate with a nonbinding surface for general applications.
- Conical V-bottom design in 96-well format
- Pack of 40 clear polystyrene plates
Greiner Bio-One 650901 Clear U-Bottom 96-Well Microplate
The 650901 model offers a round U-bottom configuration in a 96-well layout. Like its V-bottom counterpart, it is sold in a pack of 40 and made from clear polystyrene. The U-bottom shape is often preferred for applications requiring gentle mixing or where complete drainage is less critical than in V-bottom plates.
This clear, nonbinding plate provides a versatile option for standard laboratory assays and sample handling.
- Round U-bottom design in 96-well format
- Pack of 40 clear polystyrene plates
Corning 3574 White Flat-Bottom 384-Well Microplate
This solid white 384-well microplate features flat-bottom square wells with a volume of 112 µL. It is treated with NBS (Nonbinding Surface) to minimize molecular interactions and reduce protein binding. The white walls are designed to reduce well-to-well crosstalk during luminescent assays. Sold in a case of 50, this plate is suitable for high-density screening where signal-to-noise ratio is a priority.
- White walls reduce crosstalk in luminescent assays
- NBS treated surface minimizes molecular binding
Greiner Bio-One 655906 Black Flat-Bottom 96-Well Microplate
This black polystyrene microplate features a flat bottom with a chimney style design in a 96-well format. The black walls help reduce autofluorescence, which is beneficial for fluorescence-based assays. It is sold in a pack of 40 and manufactured in Germany. This option is well-suited for researchers who need to minimize background noise in sensitive optical measurements.
- Black walls reduce autofluorescence
- Chimney style flat-bottom design
Greiner Bio-One 781900 Black Flat-Bottom 384-Well Microplate
The 781900 model is a black polystyrene microplate with a flat bottom in a 384-well configuration. It is sold in a pack of 40 and has a package weight of 6.1 lbs. The black color is advantageous for reducing background noise in fluorescence assays. This high-density plate is ideal for researchers who need to maximize sample throughput while maintaining low background interference.
- 384-well high-density format
- Black polystyrene material
Corning 3575 Black Flat-Bottom 384-Well Microplate
This solid black 384-well microplate features flat-bottom square wells with a volume of 112 µL. It is treated with NBS (Nonbinding Surface) to create a nonionic hydrophilic surface that minimizes molecular interactions. The black walls provide reduced autofluorescence and a higher signal-to-background ratio. Sold in a case of 50, this plate is designed for high-throughput screening with low background noise.
- Black walls reduce autofluorescence
- NBS treated surface for low binding
Head-to-Head Comparisons
Greiner V-Bottom vs U-Bottom: Drainage vs Mixing
The Greiner 651901 and 650901 models both offer clear 96-well plates in packs of 40, but they differ in bottom shape. The 651901 features a conical V-bottom, which is ideal for applications requiring complete liquid drainage, such as centrifugation or washing steps. In contrast, the 650901 has a round U-bottom, which is often preferred for applications where gentle mixing is needed or where complete drainage is not critical.
Choose the V-bottom for drainage-focused protocols and the U-bottom for mixing-focused workflows.
Corning White vs Black: Luminescence vs Fluorescence
Both Corning 3574 and 3575 are 384-well plates with NBS-treated surfaces, but they differ in wall color. The 3574 has white walls, which are designed to reduce well-to-well crosstalk during luminescent assays. The 3575 has black walls, which reduce autofluorescence and provide a higher signal-to-background ratio for fluorescence assays.
If your primary detection method is luminescence, the white plate may be more suitable. If you are working with fluorescence, the black plate offers better background suppression.
Greiner 96-Well vs 384-Well: Throughput vs Flexibility
The Greiner 655906 and 781900 are both black polystyrene plates, but they differ in well count. The 655906 is a 96-well plate with a chimney style flat bottom, offering more flexibility for a variety of assay types. The 781900 is a 384-well plate, which allows for higher throughput and more samples per run.
If you need to process a large number of samples quickly, the 384-well plate is the better choice. If you require more flexibility in assay design, the 96-well plate may be more appropriate.
Buying Guide
Well Count and Throughput
The number of wells determines how many samples you can process in a single run. 96-well plates are standard for most laboratory applications and offer flexibility in assay design. 384-well plates are designed for high-throughput screening, allowing you to process more samples in less time.
Consider your sample volume and the capacity of your liquid handling equipment when choosing between these formats. For more on sample storage, see Science Lab Sample Vials.
Bottom Shape and Drainage
The shape of the well bottom affects how liquids behave during centrifugation and washing. V-bottom wells facilitate complete drainage, which is essential for applications where residual liquid can interfere with the assay. U-bottom wells are better for applications where gentle mixing is required or where complete drainage is not critical.
Flat-bottom wells are common in optical assays where a consistent path length is needed. Choose the bottom shape that matches your protocol's requirements.
Wall Color and Optical Performance
The color of the plate walls can significantly impact optical measurements. White walls are designed to reduce crosstalk in luminescent assays, while black walls reduce autofluorescence in fluorescence assays. Clear walls allow for visual inspection but may not be suitable for sensitive optical measurements. Consider the detection method of your assay when selecting a plate color.
For related optical components, see Science Lab Scintillation Vials.
Surface Treatment and Binding
Nonbinding surfaces are treated to minimize molecular interactions, which can reduce protein and nucleic acid binding at low concentrations. This is particularly important for assays where signal-to-noise ratio is a priority. The NBS (Nonbinding Surface) treatment creates a nonionic hydrophilic surface that helps maintain assay integrity.
Ensure that the surface treatment is compatible with your specific assay components. For liquid handling, see Lab Syringe Pump Options.
Frequently Asked Questions
What is the difference between V-bottom and U-bottom microplates?
V-bottom plates have a conical shape that facilitates complete liquid drainage, making them ideal for centrifugation and washing steps. U-bottom plates have a round shape that is better for gentle mixing and applications where complete drainage is not critical. Choose based on your protocol's requirements.
Why are black microplates used in fluorescence assays?
Black walls reduce autofluorescence, which is the background noise generated by the plate material itself. This results in a higher signal-to-background ratio, making it easier to detect low-concentration fluorescent signals. White plates are typically used for luminescent assays to reduce crosstalk.
What does NBS (Nonbinding Surface) treatment do?
NBS treatment creates a nonionic hydrophilic surface that minimizes molecular interactions. This helps reduce protein and nucleic acid binding at low concentrations, which can improve assay signal-to-noise ratio. It is particularly useful for sensitive assays where non-specific binding can interfere with results.
How many plates are included in each pack?
The Greiner Bio-One plates are sold in packs of 40, while the Corning plates are sold in cases of 50. This allows you to choose the quantity that best fits your laboratory's needs. Check the specific product listing for the exact pack size before purchasing.
This article is part of our complete guide Toys & Games — browse all our comparisons and buying guides.
Last update on 2026-11-18 / Affiliate links / Images from Amazon Product Advertising API
